The selection procedure involves 5 steps:

  1. Required Data
  2. Torque Calculation
  3. Coupling Selection
  4. Bore Capacity
  5. Misalignments
  6. Contact Goodrich

Step 1 - Required Data

Maximum Power ___ KW or HP       Parallel Offset ___ Inch
Speed Range ___ RPM   Angular Misalign ___ Degrees
Trip Speed ___ RPM   Distance Between Shaft Ends (BSE) ___ Inch
Axial Movement   Driver Shaft End Dia. (Straight or Taper) ___ Inch
-Driver Machine ___Inch   Load Shaft End Dia. (Straight or Taper) ___ Inch
-Load Machine ___Inch   Envelope Minimum Diameter ___ Inch

Special Requirements

Torquemeter, Electric Isolation, Shear Section, Backup Gear Drive

API 671 Required [ ] Yes [ ] No
API 610 Required [ ] Yes [ ] No


Step 2 - Torque Calculation

Calculate the normal continuous torque. (KW x 1.341 = HP)

 T =(_(HP)_ (63,025)______ ) / (Speed at which HP occurs) Lb-in

For situations where the HP changes over the speed range, the condition generating the maximum continuous torque must be determined.

Electric motor starts, generator short circuit, compressor surge, and pump Cavitation cause single cycle peak torque requirements. This value may mandate a larger coupling selection, based upon the peak torque values each coupling.


Step 3 - Coupling Selection

Select the coupling from page 3 or page 5 which has the maximum continuous torque greater than the calculated normal continuous torque with specified application factor.


Step 4 - Bore Capacity

Verify the maximum bore capacity of the coupling selected is greater than the bores specified.


Step 5 - Misalignments

Verify that the coupling selected meets the angular and axial misalignments of the application.


Step 6 - Contact Goodrich

Goodrich will supply Coupling Selection Data Sheet in Imperial or SI units; including mass elastic, lateral and axial natural frequencies within 24 hours for standard designs!

 