Commercial Couplings Selection ProcedureThe selection procedure involves 5 steps: Step 1 - Required Data
Special Requirements Torquemeter, Electric Isolation, Shear Section, Backup Gear Drive API 671 Required [ ] Yes [ ] No Step 2 - Torque CalculationCalculate the normal continuous torque. (KW x 1.341 = HP) T =(_(HP)_ (63,025)______ ) / (Speed at which HP occurs) Lb-in For situations where the HP changes over the speed range, the condition generating the maximum continuous torque must be determined. Electric motor starts, generator short circuit, compressor surge, and pump Cavitation cause single cycle peak torque requirements. This value may mandate a larger coupling selection, based upon the peak torque values each coupling. Step 3 - Coupling SelectionSelect the coupling from page 3 or page 5 which has the maximum continuous torque greater than the calculated normal continuous torque with specified application factor. Step 4 - Bore CapacityVerify the maximum bore capacity of the coupling selected is greater than the bores specified. Step 5 - MisalignmentsVerify that the coupling selected meets the angular and axial misalignments of the application. Step 6 - Contact GoodrichGoodrich will supply Coupling Selection Data Sheet in Imperial or SI units; including mass elastic, lateral and axial natural frequencies within 24 hours for standard designs!
|